TMOS (681-84-5) msds
- Product Details
- Company Profile
TMOS (681-84-5) msds (also called as methyl silicate, tetramethoxysilane, tetramethyl orthosilicate) information is provided by WD Silicone, which has become a major manufacturer of silane coupling agents in China, as well as a leading company for silane-related technology development, support and transform.
1. PRODUCT AND COMPANY IDENTIFICATION
Product name: TMOS (681-84-5)
Other names: Tetramethyl orthosilicate
2. HAZARDS IDENTIFICATION
Danger
Flammable liquid and vapour.
Causes skin irritation.
Causes serious eye damage.
Fatal if inhaled.
May cause respiratory irritation.
Do not breathe dust/ fume/ gas/ mist/ vapours/ spray.
Wear protective gloves/ eye protection/ face protection.
Wear respiratory protection.
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Immediately call a POISON CENTER or doctor/ physician.
Inhalation: May be fatal if inhaled. Causes respiratory tract irritation.
Skin: May be harmful if absorbed through skin. Causes skin irritation.
Eyes: Causes eye irritation.
Ingestion: May be harmful if swallowed.
3. COMPOSITION/INFORMATION ON INGREDIENTS
Synonyms: Tetramethoxysilane
Formula: C4H12O4Si
Molecular Weight: 152.22 g/mol
4. FIRST AID MEASURES
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.Move out of dangerous area.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.
In case of eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
5. FIRE-FIGHTING MEASURES
Suitable extinguishing media
For small (incipient) fires, use media such as "alcohol" foam, dry chemical, or carbon dioxide. For large fires, apply water from as far as possible. Use very large quantities (flooding) of water applied as a mist or spray; solid streams of water may be ineffective. Cool all affected containers with flooding quantities of water.
Special protective equipment for fire-fighters
Wear self contained breathing apparatus for fire fighting if necessary.
Further information
Use water spray to cool unopened containers.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions
Wear respiratory protection. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
Environmental precautions
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Methods and materials for containment and cleaning up
Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and place in container for disposal according to local regulations (see section 13).
7. HANDLING AND STORAGE
Precautions for safe handling
Avoid contact with skin and eyes. Avoid inhalation of vapour or mist.
Keep away from sources of ignition - No smoking. Take measures to prevent the build up of electrostatic charge.
Conditions for safe storage
Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Store in cool place.
Hydrolyses readily.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters
Personal protective equipment
Respiratory protection
Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Hand protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
Eye protection
Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin and body protection
Complete suit protecting against chemicals, Flame retardant antistatic protective clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Hygiene measures
Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling the product.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance: liquid
Colour: colourless
10. STABILITY AND REACTIVITY
Chemical stability
Stable under recommended storage conditions.
Possibility of hazardous reactions
Vapours may form explosive mixture with air.
Conditions to avoid
Heat, flames and sparks.
Materials to avoid
Oxidizing agents, acids, Bases
Hazardous decomposition products
Hazardous decomposition products formed under fire conditions. - Carbon oxides, silicon oxides
11. TOXICOLOGICAL INFORMATION
Acute toxicity
LC50 Inhalation - rat - 4 h - 0.4 mg/l
LD50 Dermal - rabbit - 17,544 mg/kg
Skin corrosion/irritation
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitization
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
Verified Supplier